Choose a representative location, protect the Sensor body, and confirm the Sensor stays connected to the Hub after installation.

Where a Sensor sits decides whether its readings mean anything. Follow the common rules below, then open the guide for your environment.

Common Deployment Rules

Choose a Representative Location

  • Keep temperature Sensors away from direct sunlight, heaters, electronics, fans, air-conditioning outlets, and cooling vents.
  • Leave open space around the Sensor or probe so air can circulate.
  • Do not let a temperature probe touch food or a refrigerator wall directly.
  • Keep leak probes at the lowest likely collection point without putting the transmitter body in standing water.

Protect the Sensor Body

  • Keep non-waterproof Sensor bodies outside high-humidity and condensation-prone spaces whenever an external probe is available.
  • If a body must be placed inside, use appropriate moisture protection and food-grade desiccant.
  • IP67 protection helps against splashing and temporary submersion; it does not imply unlimited underwater use.

Preserve the Wireless Connection

  • Metal appliances, cabinets, machinery, and reinforced walls reduce wireless range. See Wireless Range.
  • Keep the Hub within range of every Sensor it serves; the ST7-CL and NM1 connect on their own and do not use a Hub.
  • Confirm the Sensor remains online after closing doors and completing installation.
  • Verify that the latest data timestamp continues to update before leaving the site.