H5 Lite Release Notes
Release notes for MOCREO H5 Lite, covering firmware, app, portal, and device update history.
v1.3.1
H5 Lite · · h5-lite
Improvements
- Temperature Probe Recovery: Improved recovery for the built-in temperature probe. After an abnormal reading, the Hub now retries automatically without needing a power cycle.
- Bluetooth Sensor Stability: Improved scanning, connection, and data reporting stability for Bluetooth Sensors.
- Wi-Fi Setup and LoRa Sensor Identification: Improved network setup stability in complex Wi-Fi environments, and improved device identification for LoRa Sensors.
Compatibility Notes
- In some Bluetooth scanning scenarios, a Sensor's name may be shown as its MAC address.
v1.3.0
H5 Lite · · h5-lite
New Features
- SD1 and MS3 Support: Added support for SD1 and MS3 sensors, including default temperature alerts, probe status, and probe-type display.
- Web Portal Login: The Hub Web Portal now requires a login, and network settings are validated before being saved.
- Remote Network Diagnostics: Network diagnostics can now be started remotely from the App.
- Automatic Default Settings: When a sensor is added for the first time, the Hub now applies default settings automatically.
Improvements
- Offline Data Backfill: Rebuilt the way sensor history stored on the device is collected and uploaded, so data recorded while offline is uploaded more completely and more reliably.
- History Display: Improved the timeline view, and single-probe devices no longer show readings when the probe is abnormal.
- Web Portal: Session timeout shortened to 8 hours, clearer login and password-reset messages, clearer run-mode labels and error prompts.
- Screen: Reduced backlight brightness at the lowest setting.
- Setup: Bluetooth scanning now stops before entering Setup mode, making setup more reliable.
Bug Fixes
- History Timestamps: Fixed cases where uploaded history could carry the wrong time.
- Long History Records: Fixed data parsing errors when a sensor had a large amount of stored history.
- Repeated Values: Fixed a case where the timeline could show the same value repeatedly.
- Static IP: Fixed a case where static IP fields were still validated after static IP was turned off.
- Temperature Calibration: Fixed cases where a calibrated value could be read from the wrong source and shown incorrectly.
Compatibility Notes
- Existing sensors do not need to be added again.
- Historical data will not be lost after updating.
v1.2.3
H5 Lite · · h5-lite
New Features
- MS2 Support: Added compatibility with MS2 devices.
- Hybrid Mode: Supports both cloud and local control for improved flexibility.
- Static IP: You can now configure a static IP for your device.
- Custom NTP Server: Option to change the time server source.
- Automation Rules: Added support for creating automation rules.
Improvements
- Temperature Sync: Temperature units are now automatically synced with your cloud settings.
- Connectivity Stability: Improved overall connection reliability and responsiveness.
- Wi-Fi Reconnect: Device will automatically reconnect if Wi-Fi is lost.
- Network Recovery: Device can recover automatically after prolonged network issues.
- OTA Experience: Improved update experience with clearer failure notifications.
- Setup Flow: Easier navigation during setup, including quick return to the starting page if errors occur.
- Weather App Enhancements: Updated refresh intervals for better accuracy, added manual refresh option, and added time display.
- Battery Reporting: Faster updates when significant battery level changes occur.
- Alarm Handling: Improved handling of alarm states for better stability.
Bug Fixes
- LED Effects: Fixed an issue where LED effects were not updated correctly after network recovery.
v1.2.1
H5 Lite · · h5-lite
Improvements
- Alert Rule Optimization: Optimized the rule inheritance logic. Override and repeat rules now inherit the repeat interval from the active rule to conserve system resources.
- Leakage Sensor Data Logic: Optimized data reporting for flood sensors. The system now filters out duplicate data and only reports when there is a change in flood levels, improving efficiency.
Bug Fixes
- Alert Dismissal Logic: Fixed an issue with the alert dismissal process. Dismissing an alert now correctly skips hierarchical rule reporting, significantly reducing unnecessary notification noise.
v1.2.0
H5 Lite · · h5-lite
New Features
- Support for WPA-type Wi-Fi network connections
- Added Wi-Fi network switching and forgetting functionality
- Added simplified Wi-Fi-only configuration process
- Support for multiple Wi-Fi network connection management
- Support for remote alert dismissal functionality
- Added SW3 sensor support
Improvements
- Weather App optimization: No popup notifications for failed data retrieval except on first attempt
- Optimized network information synchronization to server, improving data transmission efficiency
- Enhanced alert display effects in Sensor App
- Optimized alert rule acquisition and triggering process, improving response speed
Bug Fixes
- Fixed issue where indicator light status might display incorrectly after device startup
- Fixed issue where repeated alerts sometimes could not be properly cleared after setup
- Fixed issue where some network information (such as network name, signal strength) was missing when device reported status
- Fixed issue where status synchronization might be abnormal after remote command execution completion in specific scenarios
- Fixed issue where alert dismissal interface might unexpectedly disappear after device list updates
v1.1.7
H5 Lite · · h5-lite
Improvements
- During Bluetooth scanning, peripheral device information is logged every 5/10 scans to improve debugging efficiency.
- When an alert is triggered, a mask is displayed on the sensor app interface with a prompt to "Silence Alerts >" indicating the scroll wheel position.
- Cards that trigger alerts will remain red even if dismissed, until the values return to normal.
- Triggering an alert outside the sensor app or on history/detail pages will automatically redirect to the sensor app data display page.
Bug Fixes
- Fixed an issue where the sensor app indicated no sensors after upgrading from a lower version.
- Corrected the misidentification of H5-LITE as H5-PRO.
- Resolved the problem where alerts were not turned off when receiving empty rules during an alert.
v1.1.6
H5 Lite · · h5-lite
Bug Fixes
- Fix known issues
v1.1.5
H5 Lite · · h5-lite
Bug Fixes
- Fix known issues
v1.1.4
H5 Lite · · h5-lite
New Features
- Added a notification page for missing battery information in the Sensor App.
- Introduced an interface for reporting OTA progress.
- Implemented a process to force report device properties upon startup.
- Enhanced the Sensor App to display the target UI after a sensor triggers an alarm.
- Added synchronization for Sensor device types during asset updates.
Improvements
- Adjusted the homepage to improve the user experience.
- Default CoAP request timeout set to 30 seconds.
- Encapsulated interface call failure tracking for better management.
- Simplified Wi-Fi display for networks with identical SSID and authentication modes.
- Refactored encoder direction settings to support multiple module configurations.
- Updated version extraction method during updates.
- Enhanced Sensor App to handle temperature differences more effectively.
- Improved asset synchronization by forcing an update when no sub-devices are detected.
- Streamlined the detection/reporting process for newly discovered Sensors.
- Adjusted task stack size for stability in specific operations.
- Optimized SDK configuration for size.
- Modified buzzer frequency and duty cycle.
- Transitioned environment setup to version 5.3.2.
- Refined data loading and saving methods.
- Enhanced multi-device support in various processes.
- Adapted interfaces to support paginated data retrieval.
- Improved Sensor App historical data page responsiveness and offline interval management.
Bug Fixes
- Resolved issues with the Locale and Display & Sound pages not displaying options.
- Fixed the reboot tips display issue.
- Corrected ESC key behavior on the setup page to prevent unintended homepage navigation.
- Addressed alarm style anomalies on the Sensor App homepage after alarm triggers.
- Fixed intermittent issues with indicator lights during startup.
- Resolved exceptions in periodic PingLog calls.
- Corrected display unit issues for humidity data in the Sensor App.
- Fixed long ESC key press behavior on the guide page.
- Ensured rule information notifications are sent only to compatible device types.
v1.1.3
H5 Lite · · h5-lite
Bug Fixes
- Fix known issues
v1.1.2
H5 Lite · · h5-lite
New Features
- Support turning off the status indicator in the settings
- Added device operation guidance interface after booting after unboxing or resetting
Improvements
- Optimize communication with the server
- Optimize the judgment logic of network disconnection
- Optimize the trigger logic of events
- The wind speed unit of the weather app will change with the temperature unit
Bug Fixes
- Fix the problem that the program has a probability of an infinite loop during Setup, causing the watchdog to time out and restart
- Fix the problem that the sensor app returns abnormally when entering the details page
- Fix the problem that the sensor app card is abnormally highlighted
v1.1.1
H5 Lite · · h5-lite
Improvements
- Optimize sensor data synchronization logic
Bug Fixes
- Fix the issue of LED displaying abnormal 8888
v1.1.0
H5 Lite · · h5-lite
New Features
- Support ST8, MS2
- Sensor App supports automatic scrolling of cards
- Sensor App supports displaying room names (in leaflets and details pages)
Improvements
- Optimization function
- Firmware OTA logic optimization
- Optimize the data synchronization speed of sensor app
- Optimize some data reporting logic
- Optimize some display UI
Bug Fixes
- Fixed some basic environment bugs.
- Fixed the issue where Schedule Alarm start and end time > end time configuration does not take effect
- Fixed the problem of abnormal display of sensor app icon
- Fixed some alarm exception issues
v1.0.4
H5 Lite · · h5-lite
New Features
- Add support for ST9 and ST10.
Improvements
- Display SN on the initial setup page.
Bug Fixes
- Rectify the issue of not carrying signal values when reporting device recovery.
- Amend the criteria for connecting to WiFi but failing to obtain an IP during setup.
- Resolve the anomaly concerning the order of nodes when deleting them.
- Fix the issue of abnormal display showing no sensors after re-setup
- Address the reverse focus problem of the encoder within the SensorApp
- Resolve the issue where the Sensor card does not flash red after the Sensor triggers an alarm
v1.0.3
H5 Lite · · h5-lite
New Features
- Support MS1.
- Add a trigger condition for failing to obtain an IP during the setup process.
- Enhance the filtering of error codes generated by anomalies when connecting to certain Wi-Fi networks at startup.
- Ensure timely synchronization of the time zone after any changes occur.
Improvements
- Modify the alarm rule judgment logic to enable faster responses to alerts.
- Optimize the logic for determining unbound accounts in the sensor app.
- Adjust the interaction methods to better align with interaction logic.
- Adjust the temperature range reporting for ST5.
Bug Fixes
- Rectify the issue of abnormal humidity display on the LED.
- Address the error anomalies within the sensor app.
- Resolve the issue of missing card data display in the sensor app.
v1.0.2
H5 Lite · · h5-lite
Improvements
- Optimization of some copy and UI elements.
- Adjustment of the signal strength evaluation range.