Skip to content

ST5

ST5's addition and installation deployment.

  • Here, you can find guidance on the addition and installation deployment of ST5. Before reading the following article, please ensure that you have completed the H5-Lite setup process.

What should I prepare?

  1. Sensor: First, insert the external temperature probe into the main body of the Sensor.

  2. Pin: When adding, you need to use a pin to poke the pinhole under the soft rubber cover of the 1s Sensor to put it into setup mode.

  3. Power cord: If, upon completing the Sensor addition process, you find that the Sensor's current battery level is suboptimal (below 50%) when entering the Sensor configuration page, we recommend using the provided power adapter and power cord to charge the Sensor.

During the charging process, the Sensor's red indicator light will remain steadily lit and will automatically turn off once the Sensor's battery is nearly fully charged. You can use this change to determine whether the Sensor is ready to conclude the charging operation.

How to set it up?

Before actual deployment, we recommend prioritizing the ST5 Sensor Setup process, which involves adding the sensor via the MOCREO Smart App.

Before adding the ST5 Sensor, please ensure that you have completed the setup process for the H5-Lite deployed at the same location as the sensor.

Add ST5 Sensor

Please place your ST5 Sensor near the H5-Lite and your smartphone to ensure that during the sensor setup process, the sensor can be successfully scanned by both the H5-Lite and your smartphone's Bluetooth.

You just need to follow the prompts in the app to complete the ST5 Sensor setup process smoothly.

How to mount it?

ST5 wireless temperature sensor is widely applicable in low-temperature environments (such as refrigerators and freezers) and environments with water (such as bathtubs and fish tanks).

The following are some considerations for deploying the ST5 Sensor in different environments:

  1. In low-temperature environments:Before placing the Sensor's external temperature probe, ensure there is sufficient space between the probe and the items in the low-temperature environment to allow for proper air circulation and even temperature distribution. Avoid direct contact between the probe and the items to prevent measurement interference. The probe should be kept away from fans and freezers to minimize measurement errors.

  2. Special environments:External sensors with stainless steel probes and PVC cable are both corrosion-resistant materials. However, there is still a risk of corrosion and aging when exposed for long periods to harmful chemicals, saltwater, grease, humidity, or high temperatures.

Test the Effectve Distance

Place the paired ST5 Sensor in the location you want to monitor. The suggested distance between the H5-Lite and the Sensor is 67 ft - 82 ft (Household environment).

Poke the Sensor pinhole for 1s and release. Go to the H5-Lite LCD display area to view the current actual signal level of the sensor.

Path: Sensor (Apps)>>>Select a sensor >>> Confirm twice to enter the sensor configuration page.

Note: lf the current signal level of the sensor is weak, we recommend you to read just the deployment position of the sensor.